In Line Quality Measurement
In line real-time measurement of product quality is becoming more important. Two key factors that can be measured in line are water content in ppm and particle size distribution according to ISO 4406:1999. Njord offers both measurement systems that can easily be integrated with our range of automated filtration systems and represent a remarkable cost effective solution to fluid management and contamination control.
- the Zelentech Water in Oil meter delivers continuous, real ime accurate monitoring of the ppm concentrati.on of ALL water (free, dissolved as well as emulsified).
- the Parker i-Count combined with Njord flow control offers laser based leading edge technology.
Parker Icount
The Incount Particle Detector from Parker represents the most up-to-date technology in solid particle detection. The design dynamics, attention to detail, and small size of the permanently mounted, on-line particle detector brings a truly innovative product to all industry. The laser based, leading-edge technology is a cost effective market solution to fluid management and contamination control.
-
Independent monitoring of system contamination trends.
-
Early warning LED or digital display indicators for
-
Low, Medium and High contamination levels.
-
Moisture %RH LED indicator (optional).
-
Cost effective solution in prolonging fluid life and reducing machine downtime.
-
Visual indicators with power and alarm output warnings.
-
Continuous performance for dependable analysis.
-
Hydraulic, phosphate ester & fuel fluid compatible construction.
-
Self diagnostic software.
-
Fully PC/PLC integration technology such as: RS232 and 0-5 Volt, 4-20mA.
Digital LED display update time | Every second |
4-20mA output signal | Continuous |
Principle of operation | Laser diode optical detection of actual particulates |
Performance | +/- 1 ISO Code (dependant on stability of fl ow) |
Reproducibility / Repeatability | Better than 1 ISO Code |
Power requirement | Regulated 9 to 40Vdc |
Maximum current draw | 150mA |
Hydraulic connection | M16 x 2 hydraulic test points (5/8” BSF for aggressive version |
Flow range through the device | 40 to 140 ml/min (optimum fl ow = 60ml/min) |
Inline Sensors | Size 1 = 24 to 100 l/min - (optimum fl ow = 70 l/min) |
Required differential pressure | 5.8 psi (0.4 bar) minimum |
Viscosity range | 10 to 500 cSt |
Temperature | Operating environment: -4°F to +140°F (-20°C to +60°C) |
Working pressure | 30 to 6,000 PSI (2 to 420 bar) |
Moisture sensor calibration | ±5% RH (over compensated temperature range of +10°C to +80°C) |
Operating humidity range | 5% RH to 100% RH |
Certification | IP66 rated |
Materials | User friendly construction |
Dimensions | 7.2” x 6.1” x 3.4” (182mm x 155mm x 86mm) |
Weight |
2.9 lbs. (1.3 kg) |